亞洲知識產權資訊網為知識產權業界提供一個一站式網上交易平台,協助業界發掘知識產權貿易商機,並與環球知識產權業界建立聯繫。無論你是知識產權擁有者正在出售您的知識產權,或是製造商需要購買技術以提高操作效能,又或是知識產權配套服務供應商,你將會從本網站發掘到有用的知識產權貿易資訊。

In-Vivo Quantitative Fluorescence Probe for Surgical Guidance and "Smart" Biopsies

技術應用
Identification of thelast remaining tumor cells during surgery to maximize resection completenessand extend patient’s lifePrior to biopsy, tissue fluorescence can be measured to confirm that thebiopsy is likely to contain tumor cells
詳細技術說明
Handheld probe quantitatively identifies tumor cellsin vivo, for needle biopsies and guiding surgical interventions/resections
*Abstract

UHN scientists have developed a unique handheldprobe that can quantitatively measure tissue fluorescence in vivo; such fluorescence can be elicited in tumor cells with theaid of an orally given drug. The key differentiator from other quantitativefluorescence devices is its small handheld size and the important ability tocompensate/correct for the dramatic effects of tissue optical propertyvariation on fluorescence readings, providing the true, quantitative assessmentof fluorophore-tagged pathologic tissue. This is important for the purpose ofproviding the surgeon with useful real-time information to determine thepresence of malignancy at the site of interest. Clinical trials are underwayfor testing of this probe’s ability to find the last few invisible tumor cellsleftover in brain tumor resection surgery, with early data showing that theprobe is far more accurate compared with a surgeon’s visual determination.

The probe has been further integrated into a biopsydevice for guidance of tissue biopsy procedures. By integrating this probe intoa biopsy needle, the surgeon can identify tumor cells prior to acquiring thetissue, leading to faster and fewer repeated procedures.


The quantitative fluorescence probe is portable, sterilizable and can be integrated into the surgical workflow. It is being used in neurosurgical trials for brain cancer removal. For high-grade glioma, the probe data has proven to be dramatically more sensitive and specific than both the surgeon’s visual assessment and an uncorrected fluorescence signal that represents the current state-of-the-art detection techniques (probe data is compared against the gold standard of tissue biopsy).

*Principal Investigation
Dr. Brian C. Wilson, University Health Network
*Publications
Kim A, Khurana M, Moriyama Y, Wilson BC. Quantification of in vivo fluorescence decoupledfrom the effects of tissue optical properties using fiber-optic spectroscopymeasurements. J Biomed Opt. 2010;15(6):067006.Valdés PA, Leblond F, Kim A, Harris BT, Wilson BC,Fan X, Tosteson TD, Hartov A, Ji S, Erkmen K, Simmons NE, Paulsen KD, RobertsDW. Quantitative fluorescencein intracranial tumor: implications for ALA-induced PpIX as an intraoperativebiomarker.J Neurosurg.2011;115(1):11-7ValdesPA, Bekelis K, Harris BT, Wilson BC, Leblond F, Kim A, Simmons NE, Erkmen K,Paulsen KD, Roberts DW.5-Aminolevulinic acid-induced protoporphyrin IX fluorescence in meningioma:qualitative & quantitative measurements in vivo.Neurosurgery. 2014;10 Suppl 1:74-82.
國家/地區
美國

欲了解更多信息,請點擊 這裡
移動設備