Search
  • 网站搜寻
亚洲知识产权资讯网为知识产权业界提供一个一站式网上交易平台,协助业界发掘知识产权贸易商机,并与环球知识产权业界建立联系。无论你是知识产权拥有者正在出售您的知识产权,或是制造商需要购买技术以提高操作效能,又或是知识产权配套服务供应商,你将会从本网站发掘到有用的知识产权贸易资讯。
返回搜索结果

Graphene Nanomesh As A Glucose Sensor


技术优势

High sensitivity, sensitivity, and fast response speed  The ambipolar field characteristic of graphene sensors enables the detection of both positively and negatively charged species  Free of “oxygen deficit” problem


技术应用

Monitor blood glucose concentration in diabetes care  In vivo glucose sensing


详细技术说明

Researchers at UCLA have developed a novel glucose sensing mechanism based on the doping effect of H2O2 to GNM. They have demonstrated the capability of GNM-based field effect transistor devices as an effective glucose sensor, and also solved the “oxygen deficit” problem since nanoscale GNM glucose sensor consumes little oxygen due to its small size. Meanwhile, the exceptionally high carrier mobility and large surface to volume ratio of graphene-based sensors provide these new glucose sensors with high sensitivity and fast response speed.


其他

State Of Development

The proposed glucose sensing mechanism has been tested.


Background

A GNM consists of a single or few-layers of graphene with a high density periodic array of nanoholes punched in. This unique structure of GNM overcomes several limitations of graphene, leading to appreciable band gap and transconductance at room temperature as well as higher functional group density, making it a promising material for graphene-based chemical sensor and biosensor applications.

Currently, most glucose sensors are based on electrochemical reactions by using amperometric enzyme electrodes. These glucose sensors rely on the detection of hydrogen peroxide generated by glucose oxidase catalyzed redox reaction through amperometric electrodes, and they tend to have relatively low selectivity because the anodic current can be introduced by oxidation of other chemicals in the environment. They also suffer from “oxygen deficit,” as the performance of the sensor is subject to errors caused by fluctuation of oxygen tension if oxygen is not in non-rate limiting excess after consumption by the glucose oxidase catalyzed reaction. Another type of glucose sensor utilizes an electron mediator which shuttles electrons between the electrode and enzyme as a substitute of oxygen. However, the mediator is usually toxic and the sensor is not appropriate to work in vivo.


Additional Technologies by these Inventors


Tech ID/UC Case

29407/2011-419-0


Related Cases

2011-419-0


国家/地区

美国

欲了解更多信息,请点击 这里
Business of IP Asia Forum
桌面版