Simultaneous Corneal Hydration Thickness And Hydration Measurement Through Multi-Spectral Reflectometry
- 技术优势
- Accurate, quantitative measurement of corneal tissue hydration across the entire span of the corneaDoes not rely on extrapolation from central corneal thickness to measure corneal tissue water content
- 技术应用
- Ophthalmology (measurement of hydration level of cornea)Detection of inflammation, immune responses, edema and other diseases in the corneaThin film measurements
- 详细技术说明
- By leveraging the unique thin film properties of the cornea, Professor Taylor and colleagues have developed a technology which significantly improves the accuracy and sensitivity of corneal hydration sensing. This technology simultaneously detects the thickness and hydration levels of corneal tissue by using multiple-frequency measurements in the terahertz range. By combining spectroscopic measurement capability with novel imaging and scanning architectures, this methodology enables accurate measurement of CTWC gradients across the cornea.
- *Abstract
-
UCLA Researchers in the Department of Bioengineering have developed a novel technology to simultaneously detect changes in thickness and hydration levels of the cornea.
- *Principal Investigation
-
Name: Neha Bajwa
Department:
Name: James Garritano
Department:
Name: Warren Grundfest
Department:
Name: Bryan Nowroozi
Department:
Name: Shijun Sung
Department:
Name: Zachary Taylor
Department:
- 其他
-
Background
Regulating water content is a major component of corneal biology as it is essential in transmission and focusing properties of the cornea and hydration levels of the cornea are indicative of cornea pathology. Fuchs dystrophy is a slowly progressing corneal dystrophy that causes the cornea to hyperphydrate and affects up to 4% of the population over 40, or approximately 5.7 million adults in the US. Currently the only cure for Fuchs dystrophy is corneal transplant, however, better diagnostic techniques which enabled early detection of disease progression could delay the need for surgery. Current practices limit corneal tissue water content (CTWC) measurement to central corneal thickness (CCT) and are extrapolated to outer regions. These diagnostic techniques assume that corneal hydration levels correlate with CCT which is not true, therefore, corneal hydration detection methods to date have been inaccurate or unsafe.
Related Materials
THz and mm-Wave sensing of corneal tissue water content: Electromagnetic modeling and analysis, Taylor et al. IEEE Transactions on Terahertz Science and Technology 2015
THz and mm-Wave sensing of corneal tissue water content: in vivo sensing and imaging results, Taylor et al. IEEE Transactions on Terahertz Science and Technology 2015Additional Technologies by these Inventors
- Raman Macro Imaging System for Fast Biocompatible Tissue Characterization
- Multi-Modal Depth-Resolved Tissue Status And Contact Pressure Monitor
- Time-Resolved Fluorescence Imaging Without Lifetime Fitting
- Multi-Modal Depth-Resolved Tissue Status Monitor
- Assessment Of Wound Status And Tissue Viability Via Analysis Of Spatially Resolved Thz Reflectometry Maps
- Scanning Method For Uniform, Normal-Incidence Imaging Of Spherical Surface With A Single Beam
- Multi-Frequency Harmonic Acoustography for Target Identification and Border Detection
- Wearable Real-Time Gait Analysis And Sensory Feedback System For Gait Rehabilitation And Biomechanical Optimization
Tech ID/UC Case
27552/2015-151-0
Related Cases
2015-151-0
- 国家/地区
- 美国