亚洲知识产权资讯网为知识产权业界提供一个一站式网上交易平台,协助业界发掘知识产权贸易商机,并与环球知识产权业界建立联系。无论你是知识产权拥有者正在出售您的知识产权,或是制造商需要购买技术以提高操作效能,又或是知识产权配套服务供应商,你将会从本网站发掘到有用的知识产权贸易资讯。

Angled probe for coronary sinus cannulation improves control, precision, and efficiency of cardiac lead placement

总结
Cardiac resynchronization therapy has emerged as the standard of care to reverse cardiac dysynchrony in patients with advanced congestive heart failure. This therapy is administered by inserting endocardial leads directly into the heart via coronary sinus cannulation. However lead insertion is technically challenging and standard cannulation devices are long and flexible, resulting in limited control by the surgeon. This technology is a right-angled cannula probe with a rigid frame that facilitates proper entry into the coronary sinus and allows monitoring of tissue interactions via tactile response. This device can improve the effectiveness of direct coronary sinus cannulation by improving ease of insertion, reducing total operating time, and reducing patient morbidity risks.
技术优势
Improves steering and monitoring of catheter positionAbility to catheterize at distances greater than 50cm without losing leverageEase of insertionReduces pain and morbidityReduces cost, procedure time, and training with improved controlCustomizable contour geometry and distance markings specific to individual patient anatomyApplicable to a wide variety of other cardiac intervention proceduresPatent Information:Patent Pending (US 20160220811)Tech Ventures Reference: IR CU14007, IR CU14193
技术应用
Cardiac lead placement during coronary resynchronization therapyInsertion of cardiac instrumentationInsertion of monitoring instruments (e.g. temperature, pressure, oxygen saturation) in the coronary sinusInsertion of prostheses, including rings, sutures, stiffeners, and pumps to reduce heart failureDelivery of contrast agents for angiographyCan be adapted for use in other procedures involving coronary sinus, intrapericardial access, intracardiac access (valve repair), transseptal puncture, and to all pacemakers/ICDs
详细技术说明
None
*Abstract
None
*Inquiry
Sara GusikColumbia Technology VenturesTel: (212) 854-8444Email: TechTransfer@columbia.edu
*IR
cu14193
*Principal Investigation
*Publications
Wang DY, Gerrah R, Rusanov A, Yalamanchi, V, Cabreriza SE, Spotnitz, HM. “Left ventricular packing lead insertion via the coronary sinus cardioplegia cannula: A novel method for temporary biventricular pacing during reoperative cardiac surgery” J Thorac Cardiovasc Surg. 2011 Jul;142(1):73-6.
国家/地区
美国

欲了解更多信息,请点击 这里
移动设备