亞洲知識產權資訊網為知識產權業界提供一個一站式網上交易平台,協助業界發掘知識產權貿易商機,並與環球知識產權業界建立聯繫。無論你是知識產權擁有者正在出售您的知識產權,或是製造商需要購買技術以提高操作效能,又或是知識產權配套服務供應商,你將會從本網站發掘到有用的知識產權貿易資訊。

Motion-Robust Cardiac B1+ Mapping of the Transmit Field

詳細技術說明
Robust Transmit Field Quantification Around the HeartA novel imaging sequence offers motion-robust quantification of the transmit field amplitude (B1+ mapping) in magnetic resonance imaging (MRI). The technique acquires images with two off-resonance shifts, using an interleaved Bloch-Siegert scheme along with an off-resonance insensitive B1+sensitization to allow for motion-robust quantification of the RF transmit field for cardiac scans in a short scan time. It obtains reproducible and stable image quality, even if the scan is performed during free-breathing, and allows robust assessment of the flip-angle variation (observed to be up to 50% across the heart in conventional cardiac MRI scans at 3T). In addition, this technique can enable robust transmit field quantification around the heart used with commercially available MRI scanners. No additional hardware is needed, and regular vendor software or sequence update routines can distribute any upgrades.Improved MRI Quantification, Shimming and Flip-angle CorrectionTransmit field mapping is required for high image quality at ultra-high fields, and is important for accurately quantifying various MRI parameters. However, this task is particularly challenging with moving tissues, such as the heart. Previously proposed methods for quantitative mapping of the RF transmit field around the heart offer insufficient motion resilience, thus severely limiting their quality and robustness. Furthermore, variations of the RF transmit field (B1+) in MRI may cause substantial differences in the effective flip-angle, which needs to be exact for accurate tissue quantification and B1+ shimming. This imaging sequence acquires the images with two off-resonance shifts (10 k-space lines at a time) that produce a significantly clearer image for moving tissue, offering improved quantification, shimming and flip-angle correction. In addition, it enables imaging of the heart on 1.5T+ MRI machines and enables imaging of the heart with free breathing.BENEFITS AND FEATURES:Heart imaging with free breathingMotion-robust quantificationCardiac B1+ mapping of transmit fieldBloch-Siegert techniqueUsed with commercially available MRI scannersImproved quantification, shimming and flip-angle correctionEnables imaging of the heart on 1.5T+ MRI machinesAPPLICATIONS:Quantitative MRI, quantitative evaluation of cardiomyopathies and/or quantitative assessment of moving organsUltra-High-Field (UHF) imagingQualitative MRI of the heartConventional MRI scannersPhase of Development - In vivo
*Abstract
None
國家/地區
美國

欲了解更多信息,請點擊 這裡
移動設備