亞洲知識產權資訊網為知識產權業界提供一個一站式網上交易平台,協助業界發掘知識產權貿易商機,並與環球知識產權業界建立聯繫。無論你是知識產權擁有者正在出售您的知識產權,或是製造商需要購買技術以提高操作效能,又或是知識產權配套服務供應商,你將會從本網站發掘到有用的知識產權貿易資訊。

Mimicked Calcified Annulus Model for Preclinical Assessment of TAVR Devices

詳細技術說明
Mimicked Annular Calcification and Aortic Stenosis in Animal ModelsAn innovative annuloplasty ring, used in conjunction with an annuloplasty procedure in large animal models, creates consistent, reproducible models of aortic stenosis for long-term evaluation of transcatheter aortic valve replacement (TAVR) devices. The Calcified Annulus Model (CAM) annuloplasty ring is flexible, circular, planar in shape and covered with a fabric sheath secured to silicon and gold rings with sutures. During the annuloplasty procedure, the ring is cut into three sections, which are lowered into the aorta and secured with sutures. While the animal heals, the annuloplasty ring segments will scar and thicken into a fibrous pannus sheath within the native aortic annulus such that the protruding annuloplasty ring sections simulate calcific aggregations present in calcific aortic stenosis. This stenotic aortic annulus allows delivery and deployment of TAVR devices within the aorta of the large animal, effectively modeling proper TAVR use in human patients. The ring segments will be easily identified via echocardiography and x-ray fluoroscopy, which can also aid in the deployment of TAVR devices within the simulated calcified annulus model. Radial force of the TAVR stent opposing the healed annuloplasty ring sections within the aorta effectively secures the TAVR device within the aorta for long term evaluation of the TAVR device.TAVR Device TestingAnnular calcification and aortic stenosis do not exist in healthy large animal models, so currently large animal models are limited in evaluating TAVR devices. This lack of disease poses a serious impediment to long-term preclinical evaluation of TAVR devices, as proper placement and anchoring of TAVR devices in humans depends on a disease state. This implanted aortic annuloplasty ring simulates calcific, stenotic, aortic annulus for TAVR implantation in large animal models, effectively creating and modeling the disease state necessary for anchoring TAVR devices in human patients and enabling other pre-clinical researchers with the technology and technique to improve the quality of TAVR product development.BENEFITS AND FEATURES:Improved pre-clinical modelsConsistent, reproducible large animal models of aortic stenosisLong-term evaluation of TAVR devicesScarring over implanted ring simulates calcific, stenotic, aortic annulus for TAVR implantationAPPLICATIONS:Medical device pre-clinical researchSimulating annular calcification and aortic stenosisPhase of Development - Device available on a low volume basis; method able to be shared.
*Abstract
None
國家/地區
美國

欲了解更多信息,請點擊 這裡
移動設備