亞洲知識產權資訊網為知識產權業界提供一個一站式網上交易平台,協助業界發掘知識產權貿易商機,並與環球知識產權業界建立聯繫。無論你是知識產權擁有者正在出售您的知識產權,或是製造商需要購買技術以提高操作效能,又或是知識產權配套服務供應商,你將會從本網站發掘到有用的知識產權貿易資訊。

Smart Capsule

總結
Researchers at Purdue University have developed a smart capsule for location-specific drug release in the gastrointestinal tract. Once activated through a magnetic proximity fuse, the capsule opens and releases its powdered payload in a location specified by an implanted miniature magnetic marker or an externally worn larger magnet. The capsule (9 mm x 26 mm) has two compartments, one contains a charged capacitor and a reed switch, while the other houses the drug reservoir capped by a taut nylon thread intertwined with a nichrome wire. The nichrome wire is connected to the capacitor through the reed switch. The capacitor is charged to 2.7V before ingestion, and once within the proximity of the permanent magnet, the reed switch closes, discharging the capacitor through the nichrome wire, melting the nylon thread, detaching the cap, and emptying the drug reservoir.
技術優勢
Enables targeted delivery of drugs to a specific location in GI track Patient does not have to be in a hospital or clinic to use Preferred capsule size (9 mm x 26 mm)
技術應用
Medical/HealthcareMedical testingPharmaceutical industrySupplement industry
詳細技術說明
Babak ZiaieZiaie Biomedical Microdevices LaboratoryPurdue Electrical and Computer Engineering
*Abstract

*Background
In recent years, smart capsules, which once ingested, can perform endoscopy and biopsy, have been the focus of intense research and development. Site-specific delivery can optimize the therapeutic efficacy of many drugs with preferential absorption sites. Although many smart capsules have been developed that are suitable for drug absorption studies in clinical settings, they cannot be used for actual therapy in larger populations that can benefit from smart capsules, which releases the drug at an optimum location in the gastrointestinal tract. This is mainly due to the problems associated with the need for real-time tracking of the capsule location. In addition, all these systems require active participation by the patient/volunteer in the form of triggering the RF transmitter once the capsule is in the target position.
*IP Issue Date
None
*IP Type
Provisional
*Stage of Development
Prototype Testing
*Web Links
Purdue Office of Technology CommercializationPurdueInnovation and EntrepreneurshipBabak ZiaieZiaie Biomedical Microdevices LaboratoryPurdue Electrical and Computer Engineering
國家
United States
申請號碼
None
國家/地區
美國

欲了解更多信息,請點擊 這裡
移動設備