Improved Spectrometer for Long Pathlength Absorbance

技術優勢
Allows for measurement of extremely dilute samplesAdjustable path length also allows for measurement of high concentration samplesDesign uses standard optics and off-the-shelf spectrometer components The dove prism configuration allows for liquid flow-through spectroscopy and evanescent wavemeasurements of condensed phase samples
詳細技術說明
This technology improves the optical configuration of spectrometers for long path length absorbancemeasurements for gases and condensed phases. Developed by Drs. Aldstadt & Geissinger as animproved approach to absorbance spectroscopy, this technology uses a compact optical cavity with arotating mirror to control the beam path length. Based on this technology a prototype was constructedand successfully demonstrated the proof of concept.
*Abstract

Long path length spectrometers areconventionally constructed of twoparallel fixed mirrors with the sampleto be measured between the mirrors.The amount of energy absorbed bythe gaseous or liquid sample ismeasured and converted to sampleconcentration. The longer the beampath through the sample, the moreenergy is absorbed, and,consequently, the lower theconcentration levels that can bemeasured. 

Conventionalspectrometer configurations aretypically limited to a narrow range ofmeasurable concentrations becauseof limited sample path length. Thisnew technology increases the effective path length by incorporating a unique beam delivery mechanismwith an electronic controller. Additionally, in contrast to conventional spectrometers, this system has adynamic optical path length that allows a very wide range of concentrations to be measured, which mayprove to extend from femtomolar (~10-15) to millimolar (~10-3) levels. HPLC is an example of a techniquethat could benefit from this unprecedented capability in measuring a wide range of concentrations, e.g.,samples containing both ultra-trace as well as relatively high levels could be measured in the samechromatographic run. 

*IP Issue Date
None
*IP Type
Download
*Principal Investigation

Name: Joseph Aldstadt, Associate Professor

Department:


Name: John Frost

Department:


Name: Peter Geissinger, Associate Professor

Department:


Name: Beth Ruddy

Department:


Name: Jorg Woehl, Associate Professor

Department:

申請號碼
Non-Confidential Summary
國家/地區
美國

欲了解更多信息,請點擊 這裡
移動設備